Code: SC552
Description: Pressure roller warm-up error - Timing & Condition - The pressure roller thermistor does not output an analog value corresponding to the ready temperature within 12 minutes after the main switch is turned on.
Causes: • Poor connection of connectors • Pressure roller fusing lamp blown • Pressure roller thermofuse opened • Blown fuse • Power fluctuation • Defective main control board • Defective I/O control board • Defective PSU
Remedy: 1. Check if the following connectors are properly connected; • Pressure roller fusing lamp connectors • CN303 on the main control board • CN206 and CN214 on the I/O control board • CN105 on the PSU 2. Replace the pressure roller fusing lamp if it is opened. 3. Replace the pressure roller thermofuse if it is opened. 4. Check if the power supplied from the outlet fluctuates. 5. Replace the main control board, I/O control board, or PSU (check the trigger signal at each pin). - Signals to Check - • Pressure roller fusing lamp trigger: CN303-B7 on main control board / CN218-B5, TP267, or CN205-A5 on I/O control board / CN106-4 on PSU.