Code: SC325
Description: Magnification correction error The length of a line measured during main scan auto magnification correction does not fall within -0.1% to 0.1% of the center value. Detection timing: When three main scan magnification corrections failed successively.
Causes: Dirty or incorrectly installed synch. detector board, or defective polygon motor
Remedy: This SC is only logged, and not displayed, so no particular action is required (no adverse influence is exerted on copier operation). Take the following actions if the customer complains about excessive magnification errors. Dirty synchronizing detector board: Clean it Incorrect synchronizing detector board installation: Reinstall Defective polygon motor: Replace