Code: SC547
Description: Hot roller temperature does not increase - Timing - Every 1 second, 2 minutes after the main switch turned on until the hot roller temperature reaches the ready condition - Condition - The hot roller temperature does not increase by more than 3 °C for a minute during warm-up.
Causes: • Poor connection of connectors • Hot roller fusing lamp blown • Hot roller thermofuse opened • Defective main control board • Defective I/O control board • Defective PSU
Remedy: 1. Check if the following connectors are properly connected; • Hot roller fusing lamp connectors • CN303 on the main control board • CN206 and CN214 on the I/O control board • CN105 on the PSU 2. Replace the hot roller fusing lamp if it is opened. 3. Replace the hot roller thermofuse if it is opened. 4. Replace the main control board, I/O control board, or AC drive board (check the trigger signal at each pin). - Signals to Check - • Hot roller fusing lamp trigger: CN303-B6 on main control board / CN205-A4, TP267, or CN218-B6 on I/O control board / CN106-5 on PSU.