Code: SC130
Description: Scanner start error - Timing - • Scanning start • During scanner motor ON - Condition - • The scanning start signal is generated while the motor is moving. • Total number of steps calculated based on the signal from the stepping motor is out of range. • The H.P. sensor stays OFF when the scanner starts moving.
Causes: • Scanner motor out of synchronization (drive error) • Poor connection of connectors • Defective scanner HP sensor • Defective sub/main scanner IPU board • Defective main control board
Remedy: 1. In SP 5-804-104, stop supplying the current to the scanner motor. Check the output signal from the scanner H.P. sensor in SP 5-803-100 by moving the scanner manually. (0: Not actuated; 1: Actuated - at H.P.) 2. If the result of step 1 is OK; 1) Check the tension of the timing belt. 2) Check if the pulley is firmly secured. 3) Check if the scanner wire is properly wired 4) Check the connection of CN700, CN701, and CN702 on the scanner motor drive board. 5) Check a current through the harnesses. 6) Replace the scanner motor drive board. 7) Replace the scanner motor. 3. If the result of step 1 is not OK; 1) Make sure the harness is properly connected. 2) Check a current through the harnesses. 3) Replace the sensor. 4) Replace the sub and/or main scanner IPU board(s). 5) Replace the main control board. [Signal Check] • Scanner HP: CN403-A1 on the sub scanner IPU board