Code: SC303
Description: Charge cleaner motor error - Timing - When the charge cleaner starts - Condition - • Over-current is detected for 10 seconds when the cleaner pads start moving from rear to front. • Over-current is still not detected 1 minute after the cleaner motor turns on.
Causes: • Poor connection • Defective cleaner motor • Cleaner pad locked • Defective I/O control board • Defective main control board
Remedy: 1. Make sure the connectors (CN861 & CN829) are firmly connected. 2. Make sure the charge corona unit is properly installed. 3. Clean the screw shaft if it is dirty. 4. See if the cleaner pad is mechanically locked. 5. Make sure the connector is firmly connected on the I/O control board (CN219). 6. Replace the I/O control board. 7. Replace the main control board.