Code: SC320
Description: Polygon motor error - Condition - • The polygon motor rotation speed stays out of the range 22 seconds after the main switch is turned on. • The polygon motor rotation speed changes while the main power switch is ON. (Polygon motor should keep rotating with constant speed while the main switch is ON.)
Causes: • Poor connection • Defective polygon motor • Defective LD control board • Defective main scanner IPU board
Remedy: 1. Make sure the connector (CN602-5) on the LD control board is properly connected. 2. Test the current through the harness. 3. Replace the polygon motor. 4. Replace the LD control board. 5. Replace the main scanner IPU board. [Signal Check] • Motor OK: CN602-2 on the LD control board.