Code: SC322
Description: Laser synchronizing signal error - Timing & Condition - While the polygon motor keeps running and LD is ON, the LD control board does not receive the laser synchronizing signal.
Causes: • Poor connection • Defective laser synchronizing detector board • Improper laser beam axis • Defective LD control board • Defective main control board • Defective optic housing unit
Remedy: 1. Make sure the connectors (CN3 & CN 602) are properly connected on the laser synchronizing detector board and LD control board 2. Remove and clean the synchronizing detector board. 3. Check if anything (such as the Barrel Toroidal lens label in the optic housing unit) interferes with the laser axis. 4. Replace the synchronizing detector board. 5. Make sure the harness connectors (CN1 & CN603) on the LD unit and LD control board are properly connected or check a current through the harness. 6. Make sure the connectors (CN604 & CN306) on the LD control board and main control board are properly connected or check the current through the harness. 7. Replace the LD control board. 8. Replace the main control board 9. Check the optical housing unit or replace it.