Code: SC373
Description: Abnormal TD sensor information (M) - Timing - When communicating with TD sensors, during printing process, or process control self-check - Condition - TD sensor output exceeds 4.5V or drops below 0.5V.
Causes: • Poor connection • Dirty sensor surface • Defective TD sensor • Toner density is out of range • Not enough developer
Remedy: 1. Make sure the TD sensor is properly connected. 2. Check if the connectors on the TD sensor interface board 1 and the slip ring and the TD sensor interface board 2 are properly connected. 3. Clean the surface of the TD sensor. 4. Replace the TD sensor. If it becomes OK after the sensor is replaced, replace the developer of color related to the problem. If the problem is related to the toner density (too low or high), find the cause and fix it.