Code: SC401
Description: Locked image transfer belt motor - Timing & Condition - • The feedback signal from the motor is still out of range 2 seconds after the trigger signal was sent. • The feedback signal goes out of range for 2 seconds while the trigger signal is ON.
Causes: • Defective image transfer belt motor • Defective image transfer belt motor drive board • Mechanical problem (drive transmission)
Remedy: 1. Make sure the connectors on the image transfer belt drive board (CN740 and 741) and I/O control board (CN220) are properly connected. 2. Check if the harnesses are damaged. 3. Replace the image transfer belt motor control board. 4. Replace image transfer belt motor. 5. See if anything has caused the belt motor’s load to increase. [Signal Check] • Motor OK: CN220-A2 or TP153 on the I/O control board