Description: Current leak from the image transfer belt lubricant brush - Timing & Condition - A current leak is detected more than 2 seconds.
Causes: • Defective high voltage supply board (Q1) • Defective I/O control board • Defective main control board
Remedy: 1. Make sure the terminal and high voltage supply board (Q1) are properly connected and that the harnesses are not damaged. 2. Clean the contacts. 3. Replace the high voltage supply board (Q1). 4. Replace the I/O control board. 5. Replace the main control board. [Signal Check] • Leak detection: CN215-B7 or TP137 on the I/O control board