Code: SC410
Description: Paper separation current leak - Timing & Condition - When a current leak is detected for 2 seconds and the leak detection started 1 second after the paper separation corona turned on. This leak signal is monitored twice a second. If it is detected twice in a row, this SC is displayed.
Causes: • Discharge unit not properly installed • Broken corona wire • Defective high voltage supply board (D) • Defective I/O control board • Defective main control board
Remedy: 1. Make sure the discharge corona unit is properly installed. 2. If the discharge corona wire is broken, replace it. 3. Make sure the terminal and high voltage supply board (D) are properly connected and that the harnesses are not damaged. 4. Clean the contacts. 5. Replace the high voltage supply board (D). 6. Replace the I/O control board. 7. Replace the main control board. [Signal Check] • Leak detection: CN208-1 or TP276 on the I/O control board