Code: SC441
Description: Locked drum peripheral component motor - Timing & Condition - • The feedback signal from the motor is still out of range 1 second after the trigger signal was sent. • The feedback signal goes out of range for 2 seconds while the trigger signal is ON.
Causes: • Defective motor • Defective motor dive board • Mechanical problem (drive transmission problem)
Remedy: 1. Make sure that connector CN220 on the I/O control board is properly connected. 2. Check for any mechanical problem by rotating the motor manually. 3. Replace the drum peripheral component motor. 4. Replace the I/O control board. 5. Replace the main control board. [Signal Check] • Motor OK: CN220-B9 or TP123 on the I/O control board