Code: SC457
Description: Position error for the image transfer belt’s cleaning unit - Timing & Condition • When the belt cleaning section touches the image transfer belt, but the belt cleaning sensor signal remains LOW. • When the belt cleaning section releases from the image transfer belt, but the belt cleaning sensor remains HIGH.
Causes: • Dirty Sensor • Defective sensor • Defective belt cleaning shift clutch • Defective drum peripheral component motor • Defective I/O control board • Defective main control board
Remedy: 1. Pull out and re-insert the image transfer belt unit. 2. Clean the image transfer belt cleaning H.P. sensor. 3. Replace the sensor. (Input Check: 5-803- 012) 4. Replace the belt cleaning shift clutch. (Output Check: SP5-804-036) 5. Replace the drum peripheral component motor. 6. Replace the I/O control board. 7. Replace the main control board. [Signal Check] • H.P.: CN219-B2 or TP108 on the I/O control board