Code: SC458
Description: PTR pressure mechanism H.P. detection error • When the PTR pressure mechanism does not stop its H.P. after 15 seconds from the PTR lift motor starts to return to its H.P. • H.P. detection sensor does not on within 7 seconds after the PTR pressure movement starts. • H.P. detection sensor does not off within 7 seconds after the PTR pressure release starts.
Causes: • Defective PTR lift motor • Defective H.P. sensor • Dirty H.P. sensor • Defective H.P. sensor feeler • Defective main control board
Remedy: 1. Make sure that sensor harness is properly connected. 2. Clean the sensor, replace it if necessary. 3. If the sensor feeler is broken, replace it. 4. Replace the PTR lift motor. 5. Replace main control board.