Code: SC496
Description: Humidity sensor - humidity detection error - Timing & Condition - The humidity sensor’s humidity output is higher than 2V or less than 0.125V.
Causes: • Poor connections • Defective humidity sensor • Defective I/O control board • Defective main control board
Remedy: 1. Make sure that connectors CN210, 211 & CN302 are properly connected to the I/O control board and the main control board. 2. Replace the humidity sensor. 3. Replace the I/O control board. 4. Replace the main control board. [Signal Check] • Humidity: CN201-4, TP236, or CN211-A8 on the I/O control board/CN302-A2 or TP113 on the main control board