Code: SC544
Description: Hot roller fusing lamp–low temperature reading - Timing - Checked every second after warm-up is complete. - Condition - The hot roller thermistor output is higher than 3V (87°C) for 8 seconds in a row.
Causes: • Fusing unit not installed properly • Poor connections • Defective thermistor • Defective I/O control board • Defective main control board • Defective AC drive board
Remedy: 1. Make sure the fusing unit is installed properly. 2. Make sure the thermistor is properly connected. 3. Replace the thermistor if it is deformed. 4. Measure the thermistor’s resistance. If it is open, replace it. (Refer to the attached Temperature/ Resistance Conversion Reference Table.) 5. Test the main control board, I/O control board, or AC drive board by checking output from the thermistor and the trigger signal at each pin. [Signal Check] • Thermistor: CN214-A4, TP234, or CN211- B1 on the I/O control board/CN302-B9 or TP117 on the main control board. • Hot roller fusing trigger: CN303-B6 on the main control board/CN212-B6, TP248, or CN229-5 on the I/O control board/CN7-6 on the AC drive board.