Code: SC551
Description: Pressure roller thermistor open - Timing - Checked every second when the fusing unit is installed. - Condition - The pressure roller thermistor output is approximately 5V (0°C) for 6 seconds in a row.
Causes: • Fusing unit not installed properly • Poor connections • Defective thermistor • Defective I/O control board • Defective main control board
Remedy: 1. Make sure the fusing unit is properly installed. 2. Make sure the thermistor is properly connected. 3. Replace the thermistor if it is deformed. 4. Measure the thermistor’s resistance. If it is open, replace it. (Refer to the attached Temperature/Resistance Conversion Reference Table.) 5. Replace the I/O control board. 6. Replace the main control board. [Signal Check] • Thermistor: CN214-A9, TP232, or CN211- B2 on the I/O control board/CN302-B8 or TP118 on the main control board.