Code: SC552
Description: Pressure roller warm-up error - Timing & Condition - The pressure roller thermistor does not register the ready temperature within 12 minutes of turning on the main switch.
Causes: • Poor connections • Blown pressure roller fusing lamp • Pressure roller thermofuse opened • Blown fuse • Power fluctuation • Defective main control board • Defective I/O control board • Defective AC drive board
Remedy: 1. Make sure the following are connected properly: • Pressure roller fusing lamp • CN303 on the main control board • CN212 and CN229 on the I/O control board • CN7 on the AC drive board 2. Replace the hot roller fusing lamp if it is blown. 3. Replace the hot roller thermofuse if it is opened. 4. Check for power fluctuations from the outlet. 5. Test the main control board, I/O control board, or AC drive board by checking the trigger signal at each pin. [Signal Check] • Pressure roller fusing trigger: CN303-B7 on the main control board/CN212-B5, TP240, or CN229-4 on the I/O control board/CN7-7 on the AC drive board