Description: Exposure lamp error
The standard white level was not detected properly when scanning the white plate.
Causes: • Exposure lamp defective • Lamp regulator defective • Exposure lamp connector defective • Dirty standard white plate • Dirty scanner mirror or scanner mirror out of position • SBU board defective • SBU connector defective • Lens block out of position