Code: 520
Description: Main Motor Error
The lock signal goes LOW after the motor starts and gets to the set speed. If the main motor lock signal stayed HIGH for 5 seconds during motor operation, the motor stopped because of overloading.
The lock signal goes LOW after the motor starts and gets to the set speed. If the main motor lock signal stayed HIGH for 5 seconds during motor operation, the motor stopped because of overloading.
Causes: • Check that the motor drive path is not overloaded. • Replace the motor harness. • Replace the motor.