Code: 6015
Description: Fuser fan error
Causes: Fusing fan motor (M10) rotates by two rotational speed; full speed / half speed. .. When fan is booted or warm-up is completed: Full speed for 2 seconds, and then half speed .. When transportation motor (M1) is rotating: Full speed .. When warm-up is completed: Half speed .. Cover open, pause: Stop When the fusing fan lock signal becomes active for 0.5 seconds, the printer detects that fusing fan motor is abnormal.
Remedy: 1 At the power ON initialization sequence, does the fusing fan motor (M10) rotate? Check the rotation by its sound or by hand feeling wind. No Remove connector PJ29A and insert it again. Replace the fan motor. Others Replace PWB-A.