Mã lỗi E525 — Epson AcuLaser C1100

Code: E525

Description: High Density
- The output value of SENSOR ASSY ADC (ADC Sensor) exceeds the specified value.
Causes: • Photoconductor Unit • SENSOR ASSY ADC • Toner Cartridge K • Toner Cartridge Y • Toner Cartridge M • Toner Cartridge C • HARNESS ASSY ADC • SENSOR HUM & TEMP • HARNESS ASSY MAIN • ROS ASSY • PWBA MCU • LV/HVPS
Remedy: 1 Check of connection between Photoconductor Unit and CONDUCTOR attached to frame Remove Photoconductor Unit. Is the contact surface of Photoconductor Unit and CONDUCTOR attached to the frame deformed or are there foreign objects on the surface? Clean, and go to Step [2]. Go to Step [2]. 2 Check of dirt and foreign bodies on surface of SENSOR ASSY ADC Are there any dirt or foreign bodies on the SENSOR ASSY ADC surface? Clean, and go to Step [3]. Go to Step [4]. 3 Does the error recur when the power is turned ON? Go to Step [4]. End of procedure 4 Check after replacement of Toner Cartridge Replace Toner Cartridge of each color. Does the error recur when the power is turned ON? Go to Step [5]. End of procedure 5 Check after replacement of Photoconductor Unit Replace Photoconductor Unit. Does the error recur when the power is turned ON? Go to Step [6]. End of procedure 6 5 VDC and 24 VDC power supply check to SENSOR ASSY ADC The voltage of P422-2 . P422-4 on PWBA MCU is 24 VDC? And the voltage of P422-8 . P422-4 is 5 VDC? Go to Step [7]. Go to Step [14]. 7 Continuity check of HARNESS ASSY ADC Disconnect P/J422 from PWBA MCU. Do all of the wiring below have normal continuity? J422-8 . J431-1 J422-4 . J431-5 J422-2 . J431-7 Go to Step [8]. Replace HARNESS ASSY ADC. 8 Check after replacement of SENSOR ASSY ADC Replace SENSOR ASSY ADC. Does the error recur when the power is turned ON? Go to Step [9]. End of procedure 9 Check of 5 VDC power supply to SENSOR ASSY HUM & TEMP The voltage of P413-4 . P413-2 on PWBA MCU is 5 VDC? Go to Step [10]. Go to Step [14]. 10 Continuity check of HARNESS ASSY MAIN Disconnect P/J413 from PWBA MCU. Do all of the wiring below have normal continuity? J413-1 . J104-4 J413-2 . J104-3 J413-3 . J104-2 J413-4 . J104-1 Go to Step [11]. Repair broken or shorted part. 11 Check after replacement of SENSOR HUM & TEMP Replace SENSOR HUM & TEMP. Does the error recur when the power is turned ON? Go to Step [12]. End of procedure 12 Check after replacement of ROS ASSY Replace ROS ASSY. Does the error recur when the power is turned ON? Go to Step [13]. End of procedure 13 Check after replacement of PWBA MCU Replace PWBA MCU. Does the error recur when the power is turned ON? Replace LV/ HVPS. End of procedure 14 Power supply check to PWBA MCU Are each of the power voltages being supplied to the following terminals on PWBA MCU from LV/HVPS? P410-1 . P410-2: 3. 3 VDC P410-3 . P410-4: 5 VDC P410-5/6 . P410-7/8: 24 VDC Replace PWBA MCU. Go to Step [15]. 15 Continuity check of HARNESS ASSY MAIN Disconnect P/J410 from PWBA MCU and P/ J502 from LV/HVPS. Do all of the wiring below have normal continuity? J410-1 . J502-1 J410-2 . J502-2 J410-3 . J502-3 J410-4 . J502-4 J410-5 . J502-5 J410-6 . J502-6 J410-7 . J502-7 J410-8 . J502-8 Replace LV/ HVPS. Repair broken or shorted part.

← Xem tất cả mã lỗi Epson AcuLaser C1100

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie