Code: E542
Description: IBT CLN Fail
- SENSOR IBT RETRACT cannot detect Advance/Retract of CAM ASSY-IBT CL.
- SENSOR IBT RETRACT cannot detect Advance/Retract of CAM ASSY-IBT CL.
Causes: • DRIVE ASSY PRO • SENSOR IBT RETRACT • HARNESS ASSY MAIN • PWBA MCU
Remedy: 1 Check of connection of DRIVE ASSY PRO (IBT Cleaner Retract Motor) Is connector P/J414 connected firmly to PWBA MCU? Go to Step [2]. Re-connect the connector. 2 24 VDC power supply check to DRIVE ASSY PRO (IBT Cleaner Retract Motor) The voltage of P414-3 . P414-2 on PWBA MCU 2 is 4 VDC? Go to Step [3]. Go to Step [8]. 3 Check after replacement of DRIVE ASSY PRO Replace DRIVE ASSY PRO. Does the error recur when a test print is made? Go to Step [4]. End of procedure 4 5 VDC power supply check to SENSOR IBT RETRACT The voltage of P415-3 . P415-4 on PWBA MCU is 5 VDC? Go to Step [5]. Go to Step [8]. 5 Continuity check of HARNESS ASSY MAIN Disconnect P/J415 from PWBA MCU. Do all of the wiring below have normal continuity? J415-3 . J107-3 J415-4 . J107-2 J415-5 . J107-1 Go to Step [6]. Replace HARNESS ASSY MAIN. 6 Check after replacement of SENSOR IBT RETRACT Replace SENSOR IBT RETRACT. Does the error recur when a test print is made? Go to Step [7]. End of procedure 7 Check after replacement of PWBA MCU Replace PWBA MCU. Does the error recur when a test print is made? Go to Step [9]. End of procedure 8 Power supply check to PWBA MCU Are each of the power voltages being supplied to the following terminals on PWBA MCU from LV/HVPS? P410-1 . P410-2: 3. 3 VDC P410-3 . P410-4: 5 VDC P410-5/6 . P410-7/8: 24 VDC Replace PWBA MCU. Go to Step [9]. 9 Continuity check of HARNESS ASSY MAIN Disconnect P/J410 from PWBA MCU and P/ J502 from LV/HVPS. Do all of the wiring below have normal continuity? J410-1 . J502-1 J410-2 . J502-2 J410-3 . J502-3 J410-4 . J502-4 J410-5 . J502-5 J410-6 . J502-6 J410-7 . J502-7 J410-8 . J502-8 Replace LV/ HVPS. Repair broken or shorted part.