Code: 500
Description: Abnormal rotation signal of Main/Sub/Deve Motor (DRIVE ASSY MAIN) or the PH Motor (DRIVE ASSY PH) is detected.
Causes: • DRIVE ASSY MAIN • DRIVE ASSY PH • HARNESS ASSY R SIDE • PWBA MCU
Remedy: 1 Check after turning the power OFF and ON. Does the error recur even when the power is turned off and back on again? Go to Step [2]. End of procedure 2 Check the operation of the Main Motor in the DRIVE ASSY MAIN Check the Main Motor with reference to FIP 2-7 . Was the trouble fixed? End of procedure Go to Step [3]. 3 Check the operation of the Sub Motor in the DRIVE ASSY MAIN Check the Sub Motor with reference to FIP 2-8 . Was the trouble fixed? End of procedure Go to Step [4]. 4 Check the operation of the Deve Motor in the DRIVE ASSY MAIN Check the Deve Motor with reference to FIP 2-9 . Was the trouble fixed? End of procedure Go to Step [5]. 5 Check the operation of the DRIVE ASSY PH Check the DRIVE ASSY PH with reference to FIP 2-6 .