Mã lỗi 550 — Epson AcuLaser C2800

Code: 550

Description: Abnormal rotation signal of the FAN MAIN/FAN DUP is detected.
Causes: • FAN MAIN • FAN DUP • HARNESS ASSY LV TOP • LVPS • PWBA MCU
Remedy: 1 Check after turning the power OFF and ON. Does the error recur even when the power is turned off and back on again? Go to Step [2]. End of procedure 2 Check the connection of the FAN MAIN and the FAN DUP Check the connection state of the following items. • FAN MAIN - LVPS • FAN DUP - PWBA DUP Are P/J503 and P/J427 connected correctly? Go to Step [3]. Reconnect FAN MAIN and FAN DUP correctly. 3 Check the power voltage supply to FAN DUP. Measure the voltage between PWBA DUP ground <=> P/J427-1PIN. Is the power voltage (+24 V) output? Replace the FAN DUP. Go to Step [4]. 4 Check the connection between PWBA DUP and PWBA MCU Check the connection state between PWBA DUP and PWBA MCU. Are P/J428, P/J2720, P/J272, and P/J27 connected correctly? Go to Step [5]. Reconnect the P/J428, P/J2720, P/J272, and P/J27 correctly. 5 Check the continuity of the HARNESS ASSY DUP UNIT Is there normal continuity between P/J428 and P/J2720? Go to Step [6]. Replace the HARNESS ASSY DUP UNIT. 6 Check the continuity of the HARNESS ASSY FRONT COVER Is there normal continuity between P/J2720 and P/J272? Go to Step [7]. Replace the HARNESS ASSY FRONT COVER. 7 Check the continuity of the HARNESS ASSY R SIDE Is the continuity between P/J27 <=> P/J2720 normal? Go to Step [6]. Replace the HARNESS ASSY R SIDE. 8 Check the power voltage supply to PWBA DUP 1. Close the interlock switch (HARNESS ASSY INTERLOCK) before performing the following work. 2. Measure the voltage between PWBA MCU ground <=> P/J27-A17, A18PIN. Is the power voltage (approx. +24 V) output? Go to Step [9]. Replace the PWBA MCU. 9 Replace of the PWBA DUP Replace the PWBA DUP. Was the trouble fixed? End of procedure Go to Step [10]. 10 Check the power voltage supply to FAN MAIN Measure the voltage between LVPS ground <=> P503-1PIN. Is the power voltage (+24 V) output? Replace the FAN MAIN. Go to Step [11]. 11 Check the continuity of the HARNESS ASSY LV TOP Is the continuity between P/J14 <=> P/J501 normal? Go to Step [12]. Replace the HARNESS ASSY LV TOP. 12 Check the power voltage output from the LVPS. 1. Measure the voltage between LVPS ground <=> P503-1PIN. 2. Close the interlock switch (HARNESS ASSY INTERLOCK) before performing the following work. Is the power voltage (approx. +24 V) output? Replace the PWBA MCU. Replace the LVPS.

← Xem tất cả mã lỗi Epson AcuLaser C2800

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie