Mã lỗi 610 — Epson AcuLaser C2800

Code: 610

Description: High temperature, low temperature, or high humidity that goes out of bounds is detected.
Causes: • SENSOR HUM • HARNESS ASSY HUM • PWBA OHP SNR • HARNESS ASSY OHP SNR • HARNESS ASSY OHP • PWBA MCU
Remedy: 1 Check after turning the power OFF and ON Does the error recur even when the power is turned off and back on again? Go to Step [2]. End of procedure 2 Check the connection of the PWBA OHP SNR Check the connection state between PWBA OHP SNR and PWBA MCU. Are P/J2411, P/J241, and P/J24 connected correctly? Go to Step [3]. Reconnect P/J2411, P/J241, and P/J24 correctly. 3 Check the continuity of the HARNESS ASSY OHP SNR Is the continuity between P/J2411 <=> P/J241 normal? Go to Step [4]. Replace the HARNESS ASSY OHP SNR. 4 Check the continuity of the HARNESS ASSY OHP Is the continuity between P/J241 <=> P/J24? Go to Step [5]. Replace the HARNESS ASSY OHP. 5 Replace of the PWBA OHP SNR Replace the PWBA OHP SNR. Was the trouble fixed? End of procedure Go to Step [6]. 6 Replace of the PWBA MCU Replace the PWBA MCU. Was the trouble fixed? End of procedure Go to Step [7]. 7 Check the connection of the SENSOR HUM Check the connection state between SENSOR HUM and PWBA MCU. Are P/J261 and P/J26 connected correctly? Go to Step [8]. Reconnect P/J261 and P/J26 correctly. 8 Check the continuity of the HARNESS ASSY HUM Is the continuity between P/J261 <=> P/J26 normal? Go to Step [9]. Replace the HARNESS ASSY HUM. 9 Check the power voltage supply to SENSOR HUM. Measure the voltage between PWBA MCU ground <=> P/J26-4PIN. Is the power voltage (approx. +5 V) output? Replace the SENSOR HUM. Replace the PWBA MCU.

← Xem tất cả mã lỗi Epson AcuLaser C2800

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie