Mã lỗi 103 — Epson AcuLaser C3000

Code: 103

Description: CTD sensor error
Remedy: 1 Initial setting Do the following checks show a problem? • Sensor Assy ADC installation Reinstall applicable parts. Go to step 2. 2 BTR Assy check 1. Replace the BTR Assy. (Refer to Ch4-4.2.12.2) 2. Turn On the power. Does an error occur even when a new BTR Assy is installed? Go to step 3. End of procedure 3 PHD Assy check 1. Replace the PHD Assy. 2. Turn On the power. Does an error occur even when a new PHD Assy is installed? Go to step 4. End of procedure 4 Harness Assy CTD continuity check 1. Remove the Sensor Assy ADC. (Refer to Ch4-4.2.9.2) 2. Disconnect the P/J1361 replay connector from the Harness Assy Front 1 and the Harness Assy CTD. 3. Check the continuity for the following lines. J136-1 <=> J1361-5 J136-2 <=> J1361-4 J136-3 <=> J1361-3 J136-4 <=> J1361-2 J136-5 <=> J1361-1 Is the continuity between J136 <=> J1361 normal? Go to step 5. Replace the Harness Assy CTD . 5 Harness Assy Front 1 continuity check 1. Remove the P/J13 connector from the PWBA MCU & HVPS. (Refer to Ch4-4.2.18.1) 2. Check the continuity for the following lines. J13-12 <=> P1361-5 J13-13 <=> P1361-4 J13-14 <=> P1361-3 J13-15 <=> P1361-2 J13-16 <=> P1361-1 Is the continuity between J13 <=> P1361 normal? Go to step 6. Replace the Harness Assy Front 1 . 6 Replace the Sensor Assy ADC (Refer to Ch4-4.2.9.2) 1. Replace the Sensor Assy ADC. (Refer to Ch4-4.2.9.2) 2. Turn On the power. Does the error still occur? Go to step 7. End of procedure 7 5V DC power supply 1. Disconnect the P/J41 connector from the PWB Drive . 2. Measure the voltage between P41-24 <=> P41-21/22. Is there 5V DC between P41-24 <=> P41-21/22? Go to step 8. Go to step 10. 8 Harness Assy DRV 1 continuity 1. Disconnect the P/J11 connector from the PWBA MCU & HVPS. (Refer to Ch4-4.2.18.1) 2. Check the continuity between J41-24 <=> J11-17. Is the continuity normal between J41-24 <=> J11-17 normal? Go to step 9. Replace the Harness Assy DRV 1 . 9 Sensor Assy ADC 1. Replace the Sensor Assy ADC. (Refer to Ch4-4.2.9.2) 2. Turn On the power. Does an error occur even when a new Sensor Assy ADC is installed? Replace the PWBA MCU & HVPS. (Refer to Ch4-4.2.18.1) End of procedure 10 PWB Drive continuity 1. Disconnect the P/J61 connector from the PWB Drive. 2. Measure the voltage between J61-8 <=> J61-7. Is there 5V DC between J61-8 <=> J61-7. Replace the PWB Drive. (Refer to Ch4-4.2.18.5) Go to step 11. 11 Harness Assy LVNC continuity 1. Disconnect the P/J165 connector from the LVPS . 2. Measure the voltage between P165-1 <=> P165-2. Is there 5V DC between P165-1 <=> P165-2. Replace the Harness Assy LVNC . Go to FIP-DC .

← Xem tất cả mã lỗi Epson AcuLaser C3000

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie