Remedy: 1 Initial setting Do the following checks show a problem? • Fan Fuser installation • Fan Rear installation Reinstall applicable parts. Go to step 2. 2 Fan Rear Fail signal Measure the following voltages at the PWB Drive connector. P/J42-29 <=> P/J42-14/15 Is there 3.3V DC between P/J42-29 <=> P/J42-14/15? Go to step 3. Go to step 5. 3 Power supply to Fan Rear Measure the voltage between connectors P/J166-1 <=> P/J166-3 of the LVPS . Is the voltage 15V DC or 24V DC between P/J166-1 <=> P/J166-3? Go to step 4. Replace the LVPS. (Refer to Ch4-4.2.18.3) 4 Fan Rear 1. Replace the Fan Rear. (Refer to Ch4-4.2.18.2) 2. Turn On the power. Does the problem still occur? Replace the PWBA MCU & HVPS. Problem solved. 5 Fan Fuser Fail signal Measure the following voltages at the PWB Drive connector. P/J42-27 <=> P/J42-14/15 Is there 3.3V DC between P/J42-27 <=> P/J42-14/15? Go to step 6. Replace the PWBA MCU & HVPS. 6 Power supply to Fan Fuser Measure the following voltages at the PWB Drive connector. P/J50-7 <=> P/J50-9 Is there 24V DC between P/J50-7 <=> P/J50-9? Go to step 7. Replace the PWB Drive. (Refer to Ch4-4.2.18.5) 7 Fan Fuser 1. Replace the Fan Fuser. (Refer to Ch4-4.2.4.3) 2. Turn On the power. Does the problem still occur? Replace the PWBA MCU & HVPS. (Refer to Ch4-4.2.18.1) Problem solved.