Mã lỗi 107 — Epson AcuLaser C3000

Code: 107

Description: Environment sensor error
Remedy: 1 Initial setting Do the following checks show a problem? • Sensor Hum Temp installation Reinstall applicable parts. Go to step 2. 2 Connector connections 1. Remove the Housing Assy Elec. (Refer to Ch4-4.2.13.1) 2. Check the connection of the P/J24 connector of the PWBA MCU & HVPS . 3. Remove the Cover Side L. (Refer to Ch4-4.2.4.14) 4. Check the connection of the P/J2361 relay connector between the Harness Assy TMPB and the Harness Assy TMPA . 5. Check the connection P/J231 connector of the Sensor Assy ADC . Are the connectors connected correctly? Go to step 3. Reconnect the connector or replace the parts. 3 Sensor Hum Temp signal check Measure the voltage at the P/J2361 relay connector between the Harness Assy TMPB and the Harness Assy TMPA . P/J2361-1 <=> P/J2361-2 (3V DC or 0.1V DC or less) P/J2361-3 <=> P/J2361-2 (2.5V DC or more) Are the voltages between P/J2361 <=> P/J2361 within the ranges? Go to step 5. Go to step 4. 4 Sensor Hum Temp signal check 1. Remove the Sensor Hum Temp. (Refer to Ch4-4.2.7.5) 2. Connect the P/J231 connector of the Sensor Hum Temp. 3. Measure the voltages between the following terminals. P/J231-4 <=> P/J231-3 (3V DC or 0.1V DC or less) P/J231-2 <=> P/J231-3 (2.5V DC or more) Are the voltages between P/J231 <=> P/J231 within the ranges? Replace the Harness Assy TMPA . Go to step 5. 5 Power supply to Sensor Hum Temp Measure the vo6 Harness Assy TMPA , Harness Assy TMPB continuity Check the continuity for the following lines. J24-1 <=> P2361-4/J2361-1 <=> J231-4 J24-2 <=> P2361-3/J2361-2 <=> J231-3 J24-3 <=> P2361-2/J2361-3 <=> J231-2 J24-4 <=> P2361-1/J2361-4 <=> J231-1 Is there continuity in all lines? Go to step 7. Replace the harness with no continuity. 7 PWBA MCU & HVPS continuity 1. Disconnect the P/J11 and P/J24 connector from the PWBA MCU & HVPS. (Refer to Ch4- 4.2.18.1) 2. Check the continuity between P11-17 <=> P24-4. Is the continuity normal between P11-17 <=> P24-4 normal? Replace the PWBA MCU & HVPS. (Refer to Ch4-4.2.18.1) Go to step 8. 8 Harness Assy DRV 1 continuity 1. Disconnect the P/J41 connector from the PWB Drive . 2. Measure the voltage between connectors P41-24 <=> P42-14/15 of the PWB Drive. Is there 5V DC between P41-24 <=> P42-14/15. Replace the Harness Assy DRV 1 . Go to step 9. 9 PWB Drive continuity 1. Disconnect the P/J61 connector from the PWB Drive. 2. Measure the voltage between J61-8 <=> J61-7. Is there 5V DC between J61-8 <=> J61-7. Replace the PWB Drive. (Refer to Ch4-4.2.18.5) Go to step 10. 10 Harness Assy LVNC continuity 1. Disconnect the P/J165 connector from the LVPS . 2. Measure the voltage between P165-1 <=> P165-2. Is there 5V DC between P165-1 <=> P165-2. Replace the Harness Assy LVNC . Go to FIP-DC .ltage between P231-1 <=> P231-3. Is there +5V DC between P/J231-1 <=> P/J231-3? Replace the Sensor Hum Temp. (Refer to Ch4-4.2.7.5) Go to step 6.

← Xem tất cả mã lỗi Epson AcuLaser C3000

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie