Code: 300
Description: - Abnormal high temperature was detected
- The printer detected that the circuit for the Temp sensor is in failure
- Abnormal low temperature was detected
- Warm-up has not completed within the specified time
- The lamp remains lit longer than the specified time.
- The printer detected that the circuit for the Temp sensor is in failure
- Abnormal low temperature was detected
- Warm-up has not completed within the specified time
- The lamp remains lit longer than the specified time.
Causes: • FUSER UNIT • HARNESS ASSY FUSER • HARNESS ASSY LV TOP • LVPS • PWBA MCU
Remedy: 1 Check after turning the power OFF and ON. Does the error recur even when the power is turned off and back on again? Go to Step [2]. End of procedure 2 Check the installation of the FUSER UNIT Is the FUSER UNIT installed correctly? Go to Step [3]. Reinstall the FUSER UNIT. 3 Check the connection of the FUSER UNIT Check the connection state of the following items. • FUSER UNIT - PWBA MCU • FUSER UNIT - LVPS • LVPS - PWBA MCU Are P/J171, P/J17, P/J47, P/J14, and P/J501 connected correctly? Go to Step [4]. Reconnect P/J171, P/J17, P/J47, P/J14, and P/J501 correctly. 4 Check the continuity of the HARNESS ASSY FUSER Is there normal continuity between the following connectors? • P/J171 <=> P/J17 • P/J171 <=> P/J47 Go to Step [5]. Replace the HARNESS ASSY FUSER. 5 Check the continuity of the HARNESS ASSY LV TOP Is the continuity between P/J14 <=> P/J501 normal? Go to Step [6]. Replace the HARNESS ASSY LV TOP. 6 Check after replacing the FUSER UNIT Replace the FUSER UNIT with a new one. Does the error still occur after the replacement? Go to Step [7]. End of procedure 7 Check after replacing the LVPS Replace the LVPS with a new one. Does the error still occur after the replacement? Replace the PWBA MCU. End of procedure