Mã lỗi 300 — Epson AcuLaser C3800

Code: 300

Description: - Abnormal high temperature was detected
- The printer detected that the circuit for the Temp sensor is in failure
- Abnormal low temperature was detected
- Warm-up has not completed within the specified time
- The lamp remains lit longer than the specified time.
Causes: • FUSER UNIT • HARNESS ASSY FUSER • HARNESS ASSY LV TOP • LVPS • PWBA MCU
Remedy: 1 Check after turning the power OFF and ON. Does the error recur even when the power is turned off and back on again? Go to Step [2]. End of procedure 2 Check the installation of the FUSER UNIT Is the FUSER UNIT installed correctly? Go to Step [3]. Reinstall the FUSER UNIT. 3 Check the connection of the FUSER UNIT Check the connection state of the following items. • FUSER UNIT - PWBA MCU • FUSER UNIT - LVPS • LVPS - PWBA MCU Are P/J171, P/J17, P/J47, P/J14, and P/J501 connected correctly? Go to Step [4]. Reconnect P/J171, P/J17, P/J47, P/J14, and P/J501 correctly. 4 Check the continuity of the HARNESS ASSY FUSER Is there normal continuity between the following connectors? • P/J171 <=> P/J17 • P/J171 <=> P/J47 Go to Step [5]. Replace the HARNESS ASSY FUSER. 5 Check the continuity of the HARNESS ASSY LV TOP Is the continuity between P/J14 <=> P/J501 normal? Go to Step [6]. Replace the HARNESS ASSY LV TOP. 6 Check after replacing the FUSER UNIT Replace the FUSER UNIT with a new one. Does the error still occur after the replacement? Go to Step [7]. End of procedure 7 Check after replacing the LVPS Replace the LVPS with a new one. Does the error still occur after the replacement? Replace the PWBA MCU. End of procedure

← Xem tất cả mã lỗi Epson AcuLaser C3800

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie