Code: 610
Description: High temperature, low temperature, or high humidity that goes out of bounds is detected.
Causes: • SENSOR HUM • HARNESS ASSY HUM • PWBA OHP SNR • HARNESS ASSY OHP SNR • HARNESS ASSY OHP • PWBA MCU
Remedy: 1 Check after turning the power OFF and ON Does the error recur even when the power is turned off and back on again? Go to Step [2]. End of procedure 2 Check the connection of the PWBA OHP SNR Check the connection state between PWBA OHP SNR and PWBA MCU. Are P/J2411, P/J241, and P/J24 connected correctly? Go to Step [3]. Reconnect P/J2411, P/J241, and P/J24 correctly. 3 Check the continuity of the HARNESS ASSY OHP SNR Is the continuity between P/J2411 <=> P/J241 normal? Go to Step [4]. Replace the HARNESS ASSY OHP SNR. 4 Check the continuity of the HARNESS ASSY OHP Is the continuity between P/J241 <=> P/J24? Go to Step [5]. Replace the HARNESS ASSY OHP. 5 Replace of the PWBA OHP SNR Replace the PWBA OHP SNR. Was the trouble fixed? End of procedure Go to Step [6]. 6 Replace of the PWBA MCU Replace the PWBA MCU. Was the trouble fixed? End of procedure Go to Step [7]. 7 Check the connection of the SENSOR HUM Check the connection state between SENSOR HUM and PWBA MCU. Are P/J261 and P/J26 connected correctly? Go to Step [8]. Reconnect P/J261 and P/J26 correctly. 8 Check the continuity of the HARNESS ASSY HUM Is the continuity between P/J261 <=> P/J26 normal? Go to Step [9]. Replace the HARNESS ASSY HUM. 9 Check the power voltage supply to SENSOR HUM. Measure the voltage between PWBA MCU ground <=> P/J26-4PIN. Is the power voltage (approx. +5 V) output? Replace the SENSOR HUM. Replace the PWBA MCU.