Code: 103
Description: CTD sensor error
Remedy: 1 Initial setting Do the following checks show a problem? • Sensor Assy ADC installation Reinstall applicable parts. Go to step 2. 2 BTR Assy check 1. Replace the BTR Assy. (Refer to Ch4-4.2.12.2) 2. Turn On the power. Does an error occur even when a new BTR Assy is installed? Go to step 3. End of procedure 3 PHD Assy check 1. Replace the PHD Assy. 2. Turn On the power. Does an error occur even when a new PHD Assy is installed? Go to step 4. End of procedure 4 Harness Assy CTD continuity check 1. Remove the Sensor Assy ADC. (Refer to Ch4-4.2.9.2) 2. Disconnect the P/J1361 replay connector from the Harness Assy Front 1 and the Harness Assy CTD. 3. Check the continuity for the following lines. J136-1 <=> J1361-5 J136-2 <=> J1361-4 J136-3 <=> J1361-3 J136-4 <=> J1361-2 J136-5 <=> J1361-1 Is the continuity between J136 <=> J1361 normal? Go to step 5. Replace the Harness Assy CTD . 5 Harness Assy Front 1 continuity check 1. Remove the P/J13 connector from the PWBA MCU & HVPS. (Refer to Ch4-4.2.18.1) 2. Check the continuity for the following lines. J13-12 <=> P1361-5 J13-13 <=> P1361-4 J13-14 <=> P1361-3 J13-15 <=> P1361-2 J13-16 <=> P1361-1 Is the continuity between J13 <=> P1361 normal? Go to step 6. Replace the Harness Assy Front 1 . 6 Replace the Sensor Assy ADC (Refer to Ch4-4.2.9.2) 1. Replace the Sensor Assy ADC. (Refer to Ch4-4.2.9.2) 2. Turn On the power. Does the error still occur? Go to step 7. End of procedure 7 5V DC power supply 1. Disconnect the P/J41 connector from the PWB Drive . 2. Measure the voltage between P41-24 <=> P41-21/22. Is there 5V DC between P41-24 <=> P41-21/22? Go to step 8. Go to step 10. 8 Harness Assy DRV 1 continuity 1. Disconnect the P/J11 connector from the PWBA MCU & HVPS. (Refer to Ch4-4.2.18.1) 2. Check the continuity between J41-24 <=> J11-17. Is the continuity normal between J41-24 <=> J11-17 normal? Go to step 9. Replace the Harness Assy DRV 1 . 9 Sensor Assy ADC 1. Replace the Sensor Assy ADC. (Refer to Ch4-4.2.9.2) 2. Turn On the power. Does an error occur even when a new Sensor Assy ADC is installed? Replace the PWBA MCU & HVPS. (Refer to Ch4-4.2.18.1) End of procedure 10 PWB Drive continuity 1. Disconnect the P/J61 connector from the PWB Drive. 2. Measure the voltage between J61-8 <=> J61-7. Is there 5V DC between J61-8 <=> J61-7. Replace the PWB Drive. (Refer to Ch4-4.2.18.5) Go to step 11. 11 Harness Assy LVNC continuity 1. Disconnect the P/J165 connector from the LVPS . 2. Measure the voltage between P165-1 <=> P165-2. Is there 5V DC between P165-1 <=> P165-2. Replace the Harness Assy LVNC . Go to FIP-DC .