Mã lỗi 100 — Epson AcuLaser C4100

Code: 100

Description: ROS failure
Remedy: 1 Harness Assy ROS continuity check 1. Disconnect the P/J151 connector from the ROS Assy. (Refer to Ch4-4.2.14.1) 2. Disconnect the P/J15 connector from the PWBA MCU & HVPS. (Refer to Ch4-4.2.18.1) 3. Check the continuity in all lines between J15 <=>J151. Is the continuity normal between J15 <=> P151? Go to step 2. Replace the Harness Assy SOS . 2 PHD Assy 1. Install the new PHD Assy. 2. Turn On the power. Does the problem still occur? Go to step 3. Problem solved. 3 LD 5V DC circuit continuity (1) 1. Disconnect the P/J140 connector from the PWBA MCU & HVPS . 2. Check the continuity between P15-6 <=> P140-1. Is there continuity between P15-6 <=> P140-1? Go to step 4. Replace the PWBA MCU & HVPS. (Refer to Ch4-4.2.18.1) 4 Harness Assy EEPROM , Harness Assy CRUM continuity Check the continuity for the following lines. J140-1 <=> P71-6/J71-1 <=> J710-6 J140-6 <=> P71-1/J71-6 <=> J710-1 Is there continuity in all lines? Go to step 5. Replace the harness with no continuity. 5 Power supply to 5V DC/24V DC 1. Remove the PHD Assy . 2. Measure the voltages at each terminal of the PWB Drive . P/J41-24 <=> P/J41-21/22 (5V DC) P/J41-17/18 <=> P/J41-19/20 (24V DC when interlock switch is on) Are the voltages between all terminals at the standard values? Go to step 6. Go to step 8. 6 Harness Assy DRV1 continuity 1. Disconnect the P/J41 connector from the PWB Drive . 2. Disconnect the P/J11 connector from the PWBA MCU & HVPS . 3. Check the continuity for the following lines. J41-17/18 <=> J11-24/23 J41-19/20 <=> J11-22/21 J41-24 <=> J11-17 J41-23 <=> J11-18 J41-21/22 <=> J11-20/19 Is there continuity in all lines? Go to step 7. Replace the Harness Assy DRV1 . 7 PWBA MCU & HVPS continuity 1. Disconnect the P/J15 and P/J140 connector from the PWBA MCU & HVPS. 2. Check the continuity for the following lines. P11-23/24 <=> P15-4 P11-17 <=> P15-7 <=> P140-6 P/J15-6 <=> P/J1401 Is there continuity in all circuits? Go to step 10. Replace the PWBA MCU & HVPS. (Refer to Ch4-4.2.18.1) 8 PWB Drive continuity 1. Disconnect the P/J60 and P/J61 connector from the PWB Drive. 2. Check the continuity for the following lines. P60-1 <=> P41-17/18 (Press the interlock switch) P61-8 <=> P41-24 Is there continuity in all circuits? Go to step 9. Replace the PWB Drive. (Refer to Ch4-4.2.18.5) 9 Harness Assy 24V , Harness Assy LVNC continuity 1. Disconnect the P/J163 and P/J165 connector from the LVPS . 2. Check the continuity for the following lines. J163-1 <=> J60-1 J165-1 <=> J61-8 Is there continuity in all lines? Go to FIP-DC . Replace the harness with no continuity.

← Xem tất cả mã lỗi Epson AcuLaser C4100

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie