Mã lỗi 104 — Epson AcuLaser C4200

Code: 104

Description: Fan Motor failure.
Remedy: 1 Initial Check Are the parts listed below installed incorrectly? • FAN FRONT • FAN REAR Reinstall the part(s) correctly. Go to Step [2]. 2 Finding a failure FAN Is it the FAN REAR that does not rotate when making a test print? Go to Step [3]. Go to Step [6]. 3 Check of the FAN REAR Replace the FAN REAR with a new one. Does the error still occur after the replacement? Go to Step [4]. End of procedure 4 Check of the LVPS Replace the LVPS with a new one. Does the error still occur after the replacement? Go to Step [5]. End of procedure 5 Continuity Check of the HARNESS ASSY LV RPG 1. Disconnect P/J164 connector on the LVPS, and P/J311 connector on the PWBA MCU IDTN. 2. Check the continuity of J164<=>J311. Is there normal continuity between them? Replace the PWBA MCU IDTN. Replace the HARNESS ASSY LV RPG. 6 Continuity Check of the HARNESS ASSY FAN/PHD/MOT 1. Disconnect P/J482 connector of the FAN FRONT, and P/J48 connector on the PWBA MCU IDTN. 2. Check the continuity of J48<=>P482. Is there normal continuity between them? Go to Step [7]. Replace the HARNESS ASSY FAN/ PHD/MOT. 7 Check of the FAN FRONT Replace the FAN FRONT with a new one. Does the error still occur after the replacement? Replace the PWBA MCU IDTN. End of procedure