Mã lỗi 106 — Epson AcuLaser C4200

Code: 106

Description: Firmware error
Remedy: 1 Initial Check Are the parts listed below installed incorrectly? • PWBA MCU IDTN • HVPS • PWBA EEPROM Reinstall the part(s) correctly. Go to Step [2]. 2 Check of the HVPS Does the error recur even after reinstalling the HVPS? Go to Step [3]. End of procedure 3 Check of the PWBA EEPROM Does the error recur even after reinstalling the PWBA EEPROM? Go to Step [4]. End of procedure 4 Continuity Check of the HARNESS ASSY HVPS 1. Disconnect P/J16 connector on the PWBA MCU IDTN, and P/J141 connector on the HVPS. 2. Check the continuity of J16<=>J141. Is there normal continuity between them? Go to Step [5]. Replace the HARNESS ASSY HVPS. 5 Continuity Check of the HARNESS ASSY EEPROM 1. Disconnect P/J191 connector on the PWBA MCU IDTN, and P/J144 connector on the PWBA EEPROM. 2. Check the continuity of J191<=>J144. Is there normal continuity between them? Go to Step [6]. Replace the HARNESS ASSY EEPROM. 6 Check of the PWBA MCU IDTN Does the error recur even after reinstalling the PWBA MCU IDTN? Go to Step [7]. End of procedure 7 Check of the HVPS Replace the HVPS. Does the error still occur after the replacement? Go to Step [8]. End of procedure 8 Check of the PWBA EEPROM Replace the PWBA EEPROM. Does the error still occur after the replacement? Replace the PWBA MCU IDTN. End of procedure