Code: 525
Description: Toner density malfunction (High density)
Remedy: 1 • Initial checking: Is there any parts of wrong specifications used, improper mounting, damage, distortion, dirt, or adherence of foreign matter? • Major parts to be checked: DEVE.CONTACT PLATE ASSY, ADC SENSOR ASSY MCU PWB Replace or reinstall the relevant part. Go to step 2 2 • Checking whether the problem lies in engine or controller: Can a test print (single sheet / consecutive printing, about 10 sheets each) be performed normally with the engine alone? Check the Printer Controller. (If an error still occurs after replacing, go to step 3.)] Go to step 3 3 • Checking the DEVE. CONTACT PLATE ASSY Is the contact surface of the DEVE. CONTACT ASSY distorted? Or are there foreign matters on the contact surface of the DEVE. CONTACT ASSY? Replace the DEVE.CONTACT PLATE ASSY Go to step 4 4 • Checking the ADC Sensor surface: Is there dirt or any foreign matter adhering to the surface of the ADC Sensor? Remove dirt/foreign matters. • With the tool: Go to step 5 • Without the tool: Go to FIP-2.16 “Faulty ADC Sensor” FIP-2.17 “Faulty ADC Solenoid” 5 • Checking the ADC Sensor: Does the ADC Sensor function properly? . By using the diagnostics commander, check by Digital Output Test device code "72". Go to step 6 Go to FIP-2.16 “Faulty ADC Sensor” 6 • Checking the ADC Solenoid: Does the ADC Solenoid function properly? . By using the diagnostics commander, check by Digital Output Test device code "67". Go to step 7 Go to FIP-2.17 “Faulty ADC Solenoid” 7 • Replacing the MCU PWB and Performing Checks: Replace the MCU PWB. Is the problem solved? Problem solved Go to FIP-2.32 “Faulty LV/HV POWER SUPPLY”