Mã lỗi 530 — Epson AcuLaser C8600

Code: 530

Description: Environment (humidity)sensor malfunction
Remedy: 1 • Initial checking: Is there any parts of wrong specifications used, improper mounting, damage, distortion, dirt, or adherence of foreign matter? • Major parts to be checked: ENVIRONMENT SENSOR, P/H HARNESS ASSY, MCU PWB Replace or reinstall the relevant part. • With the tool: Go to step 2 or 3 • Without the tool: Go to step 4 or 5 2 • Checking the TEMP SENSOR: Does the TEMP SENSOR function properly? . By using the diagnostics commander, check by Analog Input Test device code "04". Go to step 6 Replace the ENVIRONMENT SENSOR 3 • Checking the Humidity SENSOR: Does the Humidity SENSOR function properly? . By using the diagnostics commander, check by Analog Input Test device code "06". Go to step 6 Replace the ENVIRONMENT SENSOR 4 • Checking the thermistor resistance of ENVIRONMENT SENSOR: Is the resistance between P/J105-1PIN . P/J105- 4PIN approx. 5 kO at room temperature (18~20°C)? Go to step 5 Replace the ENVIRONMENT SENSOR 5 • Checking the voltage of ENVIRONMENT SENSOR: Is the voltage between P/J23-5PIN . P/J23-4PIN on the MCU PWB in the range of about 0.1-4.0 VDC? Replace the MCU PWB-XL Replace the ENVIRONMENT SENSOR 6 • Checking for continuity of P/H HARNESS ASSY: Is there normal continuity between J23 . J105? Replace the MCU PWB-XL Replace the P/H HARNESS ASSY

← Xem tất cả mã lỗi Epson AcuLaser C8600

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie