Code: 6023
Description: Developing rack rotation error
When the Toner Cartridge Rack does not turn.
When the Toner Cartridge Rack does not turn.
Causes: • Rack motor (M2) • Rack Clutch (CL1) • Rack Black Position Detection Sensor (PC4) • Engine Board (PWB-A)
Remedy: 1 Check the operation of PC4. PC4_ON 2 Check the operation of M2. CL1_REM 3 Check the operation of CL1. - 4 Replace the PWB-A.