Code: E060
Description: Fuser Motor error. When the fire check detection signal is detected as High during motor rotation.
Causes: • Paper Loading Drive Motor (M1) • PF Drive Motor (M2) • Duplex Unit Drive Motor (M10) • Duplex Feeding Unit Motor (M11) • Fuser Drive Motor (M3) • Manual Feed Detection Board (PWB-Y) • Duplex Unit Control Board (PWB-X) • Control Board (PWB-A)
Remedy: 1 Check the motor connector connection status, and correct if it is improper. 2 Check the motor drive coupling status, and correct if it is improper. 3 Check the operation of M5. p115 PWB-A CNPM-A-5B(ON) 12-H 4 Replace the PWB-A.