Code: E300
Description: Polygon Motor error • When the spindle alarm signal (SPALM) is not cleared the predetermined time after the Polygon Motor has started. • When the spindle alarm signal is detected for longer than the predetermined time during steady rotation of the Polygon Motor.
Causes: • P/H Assy • Flat Cable • Control Board (PWB-A)
Remedy: 1 Check the cable connection status, and correct if it is improper. 2 Replace the P/H Assy. 3 Replace the PWB-A.