Code: E722
Description: Duplex Motor error. When the fire check detection signal is detected as Low during motor rotation.
Causes: • Paper Loading Drive Motor (M1) • PF Drive Motor (M2) • Duplex Unit Drive Motor (M10) • Duplex Feeding Unit Motor (M11) • Fuser Drive Motor (M3) • Manual Feed Detection Board (PWB-Y) • Duplex Unit Control Board (PWB-X) • Control Board (PWB-A)
Remedy: 1 Check the motor connector connection status, and correct if it is improper. 2 Check the motor drive coupling status, and correct if it is improper. 3 Check the operation of M10. p115 PWB-X PJ2-X-1~4 (Pulse) 22-H 4 Replace the PWB-X. 5 Replace the PWB-A.