Code: E051
Description: Fuser unit error
An error, such as Thermistor wire breakage, overheat or low temperature, occurred.
- Fuser Low Temp Fail 2 (STS1) : The temperature detected by the Thermistor fell below 80 degrees three consecutive times.
- Fuser Warm Up Fail : The temperature detected by the Thermopile does not reach the Ready temperature within 45 seconds after a Wait status.
- Fuser Thermistor wire breakage (STS1) : The wire breakage of the Thermistor was detected three consecutive times.
- Fuser Over Heat Fail 2 (STS1) : The temperature detected by the Thermistor exceeded 230 degrees three consecutive times.
- Fuser Lamp Fail 2 : During Standby, SSR (in LVPS) was ON continuously for 10 seconds.
- Fuser Lamp Fail 1 : During Run, SSR (in LVPS) was ON continuously for 60 seconds.
- Fuser Low Temp Fail 1 (Thermopile) : Fuser Low Temp Fail 1 (Thermopile)
- Fuser Over Heat Fail 1 (Thermopile) : The temperature detected by the Thermopile exceeded 230 degrees three consecutive times.
- Thermopile NG : The check temperature during Thermopile cleaning became abnormal.
An error, such as Thermistor wire breakage, overheat or low temperature, occurred.
- Fuser Low Temp Fail 2 (STS1) : The temperature detected by the Thermistor fell below 80 degrees three consecutive times.
- Fuser Warm Up Fail : The temperature detected by the Thermopile does not reach the Ready temperature within 45 seconds after a Wait status.
- Fuser Thermistor wire breakage (STS1) : The wire breakage of the Thermistor was detected three consecutive times.
- Fuser Over Heat Fail 2 (STS1) : The temperature detected by the Thermistor exceeded 230 degrees three consecutive times.
- Fuser Lamp Fail 2 : During Standby, SSR (in LVPS) was ON continuously for 10 seconds.
- Fuser Lamp Fail 1 : During Run, SSR (in LVPS) was ON continuously for 60 seconds.
- Fuser Low Temp Fail 1 (Thermopile) : Fuser Low Temp Fail 1 (Thermopile)
- Fuser Over Heat Fail 1 (Thermopile) : The temperature detected by the Thermopile exceeded 230 degrees three consecutive times.
- Thermopile NG : The check temperature during Thermopile cleaning became abnormal.
Causes: • HARNESS ASSY R-TOP1 • HARNESS ASSY R-BTM • SENSOR ASSY TP • LVPS • Fuser unit • MCU PWB • FUSER DRAWER CONNECTOR
Remedy: 1 Check of Heat Roll Check the Heat Roll of the Fuser unit. Is the Heat Roll wound with paper? Remove the paper To Step 2 2 Continuity check of HARNESS ASSY R-TOP1 1. Disconnect the P/J15 of the MCU PWB. 2. Disconnect J151 and P/J153 of the SENSOR ASSY TP and P/J154 of the FUSER DRAWER CONNECTOR. 3. Check if the following wiring have continuity. J15-A1 . J151-4 J15-A2 . J151-3 J15-A3 . J151-2 J15-A4 . J151-1 J15-A9 . P153-2 J15-A10 . P153-1 J15-B1 . J154-7 J15-B2 . J154-6 J15-B3 . J154-5 J15-B4 . J154-4 J15-B5 . J154-3 J15-B6 . J154-2 J15-B7 . J154-1 Do all of the wiring have continuity? To Step 3 Replace the HARNESS ASSY RTOP1 3 Power supply to Thermopile of SENSOR ASSY TP 1. Make sure that the SENSOR ASSY TP is correctly connected. 2. Check the voltage between J151-2 and J151-4. Is the voltage 5 VDC between P151-2 and P151-4? To Step 4 Replace the SENSOR ASSY TP 4 Power supply to Wiper Solenoid of SENSOR ASSY TP 1.Make sure that the SENSOR ASSY TP is correctly connected. 2. Check the voltage between J153-1 and J153-2. Is the voltage 24 VDC between P153-1 and P153-2? To Step 5 Replace the SENSOR ASSY TP 5 Check of Thermistor of Fuser unit 1. Turn the main power on. 2. Check whether the error is displayed immediately or right after a short warm-up. Does the error still occur? To Step 6 Problem solved 6 Continuity check of FUSER DRAWER CONNECTOR 1. Disconnect the P/J103 of the LVPS 2. Disconnect the P/J158 of the FUSER DRAWER CONNECTOR 3. Check if the following wiring have continuity. J103-5 . J158-2 J103-3 . J158-1 J103-1 . J158-4 Do all of the wiring have continuity? To Step 7 Replace the FUSER DRAWER CONNECTOR 7 Check of Fuser unit 1. Replace the Fuser unit. Wait until the Fuser unit cools, and then start work. 2. Turn the main power on. Does the error occur? To Step 8 Problem solved 8 Continuity check of HARNESS ASSY R-BTM 1. Disconnect P/J10 of MCU PWB. 2. Disconnect P/J101 of LVPS. 3. Check if the following wiring have continuity. J10-12 . J151-9 J10-11 . J151-10 Do all of the wiring have continuity? To Step 9 Replace the HARNESS ASSY RBTM 9 Check of LVPS 1. Replace the LVPS. 2. Turn the main power on. Does the error occur? Replace the MCU PWB Problem solved