Code: E054
Description: Fuser Fan error
- The revolution speed of FAN FUSER or FAN LV has not reached to the specified value.
- The revolution speed of FAN FUSER or FAN LV has not reached to the specified value.
Causes: • FAN FUSER • LVPS • HARNESS ASSY R-TOP1 • MCU PWB
Remedy: 1 Operation check of the FAN FUSER Turn the main power on. Does the FAN FUSER rotate properly without occurrence of an error? Problem solved To Step 2 2 Continuity check of HARNESS ASSY R-TOP1 1. Disconnect the P/J104 of the LVPS. 2. Disconnect the relay connector P/ J1041 of the FAN FUSER. 3. Check if the following wiring have continuity. J104-1 . J1041-3 J104-2 . J1041-2 J104-3 . J1041-1 Do all of the wiring have continuity? To Step 3 Replace the HARNESS ASSY TOP1 3 Power supply to the FAN FUSER 1. Make sure that the FAN FUSER is correctly connected. 2. Check the voltage between J1041-1 and J1041-3. Is the voltage 24 VDC between J1041-1 and J1041-3? To Step 4 Replace the FAN FUSER 4 Check of FAN FUSER signal (FAN ALARM) Check continuity between P1041-2 and P1041-3. Do all of the wiring have continuity? To Step 5 Replace the FAN FUSER 5 Continuity check of HARNESS ASSY R-BTM 1. Disconnect the P/J101 of the LVPS. 2. Disconnect P/J10 of MCU PWB. 3. Check if the following wiring have continuity. J101-7 . P10-14 Do all of the wiring have continuity? To Step 6 Replace the HARNESS ASSY RBTM 6 Check of LVPS 1. Replace the LVPS. 2. Turn the main power on. Does the error occur? Replace the MCU PWB Problem solved