Code: E054

Description: Fuser Fan error
- The revolution speed of FAN FUSER or FAN LV has not reached to the specified value.
Causes: • FAN FUSER • LVPS • HARNESS ASSY R-TOP1 • MCU PWB
Remedy: 1 Operation check of the FAN FUSER Turn the main power on. Does the FAN FUSER rotate properly without occurrence of an error? Problem solved To Step 2 2 Continuity check of HARNESS ASSY R-TOP1 1. Disconnect the P/J104 of the LVPS. 2. Disconnect the relay connector P/ J1041 of the FAN FUSER. 3. Check if the following wiring have continuity. J104-1 . J1041-3 J104-2 . J1041-2 J104-3 . J1041-1 Do all of the wiring have continuity? To Step 3 Replace the HARNESS ASSY TOP1 3 Power supply to the FAN FUSER 1. Make sure that the FAN FUSER is correctly connected. 2. Check the voltage between J1041-1 and J1041-3. Is the voltage 24 VDC between J1041-1 and J1041-3? To Step 4 Replace the FAN FUSER 4 Check of FAN FUSER signal (FAN ALARM) Check continuity between P1041-2 and P1041-3. Do all of the wiring have continuity? To Step 5 Replace the FAN FUSER 5 Continuity check of HARNESS ASSY R-BTM 1. Disconnect the P/J101 of the LVPS. 2. Disconnect P/J10 of MCU PWB. 3. Check if the following wiring have continuity. J101-7 . P10-14 Do all of the wiring have continuity? To Step 6 Replace the HARNESS ASSY RBTM 6 Check of LVPS 1. Replace the LVPS. 2. Turn the main power on. Does the error occur? Replace the MCU PWB Problem solved

← Xem tất cả mã lỗi Epson AcuLaser C9100

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie