Mã lỗi E055 — Epson AcuLaser C9100

Code: E055

Description: LV Fan error
- The revolution speed of FAN LV is abnormal.
Causes: • FAN LV • HARNESS ASSY R-BTM • LVPS • MCU PWB
Remedy: 1 Operation check of the FAN LV Turn the main power on. Does FAN LV rotates normally? Problem solved To Step 2 2 Power Supply for FAN LV 1. Check that the FAN LV is connected properly. 2. Check the voltage between P/J105-1 and P/J105-3. The voltage between P/J105-1 and P/ J105-3 is 24 VDC? To Step 3 Replace the LVPS 3 Check the signal of FAN LV (FAN ALARM) Check the voltage between P/J105-2 and GND. The voltage between P/J105-2 and GND is 3.3 VDC? To Step 4 Replace the MCU PWB 4 Continuity check of HARNESS ASSY R-BTM 1. Disconnect the P/J101 of the LVPS. 2. Remove the P/J10 of the MCU PWB. 3. Check if the following wiring have continuity. J101-8 . P10-13 J101-6 . P10-15 J101-5 . P10-16 Do all of the wiring have continuity? Replace the LV Replace the HARNESS ASSY RBTM