Code: E143
Description: Additional Cassette 3 error
- After a lapse of the specified time from when the Tray3 started lifting up, TRAY LEVEL SENSOR of Tray3 does not turn ON (does not become H).
- After a lapse of the specified time from when the Tray3 started lifting up, TRAY LEVEL SENSOR of Tray3 does not turn ON (does not become H).
Causes: • TRAY FEED/LIFT MOTOR • HARNESS ASSY 3TM • ACTUATOR SNR • TRAY LEVEL SENSOR • HARNESS ASSY SNR • PWB ASSY 3TM
Remedy: 1 TRAY FEED/LIFT MOTOR installation check Are TRAY FEED/LIFT MOTOR and GEAR 29 installed correctly? To Step 2 Remove and reinstall the failing part. 2 Operation check of the TRAY FEED/ LIFT MOTOR 1. Make sure that the TRAY FEED/ LIFT MOTOR operates properly. 2. Check the rotation of each gear. Do TRAY FEED/LIFT MOTOR and each gear rotate properly? To Step 3 Replace the TRAY FEED/ LIFT MOTOR 3 Check of ACTUATOR SNR for damage Check the ACUATOR SNR for bending or damage. Is the ACTUATOR SNR installed correctly? To Step 4 Remove and reinstall the failing part. 4 Continuity check of HARNESS ASSY SNR 1. Disconnect the relay connector P672/J617 of the HARNESS ASSY SNR. 2. Disconnect the J205 of the TRAY FEED/LIFT MOTOR. 3. Check if the following wiring have continuity. J617-6 . J205-1 J617-5 . J205-2 J617-4 . J205-3 J617-3 . J205-4 J617-2 . J205-5 J617-1 . J205-6 Do all of the wiring have continuity? To Step 5 Replace the HARNESS ASSY SNR 5 Continuity check of HARNESS ASSY 3TM 1. Disconnect the J549B of the PWB ASSY 3TM. 2. Disconnect the relay connector P672/J617 of the HARNESS ASSY 3TM. 3. Check if the following wiring have continuity. J549B-6 . P672-7 J549B-5 . P672-8 J549B-4 . P672-9 J549B-3 . P672-10 J549B-2 . P672-11 J549B-1 . P672-12 Do all of the wiring have continuity? To Step 6 Replace the HARNESS ASSY 3TM 6 Installation check of TRAY LEVEL SENSOR Check the installation of the TRAY LEVEL SENSOR. Is the TRAY LEVEL SENSOR installed correctly? To Step 7 Remove and reinstall the TRAY LEVEL SENSOR. 7 Continuity check of HARNESS ASSY SNR 1. Disconnect the relay connector P672/J617 of the HARNESS ASSY SNR. 2. Disconnect the J108 of the TRAY LEVEL SENSOR. 3. Check if the following wiring have continuity. J617-12 . J108-1 J617-11 . J108-2 J617-10 . J108-3 Do all of the wiring have continuity? To Step 8 Replace the HARNESS ASSY SNR 8 Continuity check of HARNESS ASSY 3TM 1. Disconnect the J549B of the PWB ASSY 3TM. 2. Disconnect the relay connector P672/J617 of the HARNESS ASSY 3TM. 3. Check if the following wiring have continuity. J549B-12 . P672-1 J549B-11 . P672-2 J549B-10 . P672-3 Do all of the wiring have continuity? To Step 9 Replace the HARNESS ASSY 3TM 9 Check of TRAY LEVEL SENSOR 1. Replace the TRAY LEVEL SENSOR. 2. Turn the main power on. Does the error occur? Replace the PWB ASSY 3TM Problem solved