Code: E200
Description: Transfer Belt Separation
- The 1st Image Transfer Pressure/Retraction Position Sensor doesn't turn ON (Retracting) even after the lapse of a given period of time after the 1st Image Transfer Pressure/Retraction Clutch has turned ON during the Transfer Belt is retracting.
- The 1st Image Transfer Pressure/Retraction Position Sensor doesn't turn OFF (Pressuring) even after the lapse of a given period of time after the 1st Image Transfer Pressure/Retraction Clutch has turned ON during the Transfer Belt is pressuring.
- The 1st Image Transfer Pressure/Retraction Position Sensor doesn't turn ON (Retracting) even after the lapse of a given period of time after the 1st Image Transfer Pressure/Retraction Clutch has turned ON during the Transfer Belt is retracting.
- The 1st Image Transfer Pressure/Retraction Position Sensor doesn't turn OFF (Pressuring) even after the lapse of a given period of time after the 1st Image Transfer Pressure/Retraction Clutch has turned ON during the Transfer Belt is pressuring.
Causes: • 1st Image Transfer Pressure/Retraction Position Sensor (PC6) • 1st Image Transfer Pressure/Retraction Clutch (CL3) • Main Motor (M1) • Mechanical Control Board (PWB-M)
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. - - 2 PC6 I/O check, Sensor check - - 3 CL3 operation check PWB-M CNDM1-11 (ON) K to L-2 4 M1 operation check PWB-M CNDM1-5 (REM) PWB-M CNDM1-8 (LOCK) K to L-2 5 Change PWB-M