Code: E303
Description: Abnormally high Fusing Pressure Roller temperature
- The temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly before the Heater temperature control starts.
- The temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly after the Heater temperature control starts.
- The temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly before the Heater temperature control starts.
- The temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly after the Heater temperature control starts.
Causes: • Fusing Unit • DC Power Supply (PU1) • Mechanical Control Board (PWB-M)
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). - - 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary. - - 3 Change Fusing Unit - - 4 Change PWB-M - - 5 Change PU1