Mã lỗi E304 — Epson AcuLaser C9200N

Code: E304

Description: Heating Roller warm-up failure
- The Heating Roller Thermistor/1 (TH1) and the Heating Roller Thermistor/2 (TH3) fails to raise a given degree of temperature even after the lapse of a given period of time after the Heating Roller Heater lamp/1 (H1) is turned ON.
- The detected temperature of the Heating Roller Thermistor/1 (TH1) is lower for a given level of degree than one of the Fusing Pressure Roller Thermistor/1 (TH2) after the Front Cover is opened or closed, the Main Power Switch is turned ON, or TROUBLE RESET is implemented.
- The counter value of zero cross signal input is not updated for a given period of time.
Causes: • Fusing Unit • DC Power Supply (PU1) • Mechanical Control Board (PWB-M)
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). - - 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary. - - 3 Change Fusing Unit - - 4 Change PWB-M - - 5 Change PU1