Code: E406
Description: Abnormally low toner density detected Black TCR Sensor
- Mixture ratio of the toner and carrier in the developing machine is lower than the specified value.
- Mixture ratio of the toner and carrier in the developing machine is lower than the specified value.
Causes: • Photoconductor Unit /K • Toner Supply Motor C/K (M7) • Mechanical Control Board (PWB-M) • Controller Board (PWB-P)
Remedy: 1 Perform image troubleshooting procedure if image density is low. - - 2 Clean the TCR Sensor window on the underside of the Photoconductor Unit if dirty. - - 3 M7 operation check PWB-M CNDM3-10 to 13 C-23 4 Reinstall Photoconductor Unit - - 5 Change Photoconductor Unit /K - - 6 Change PWB-M - - 7 Change PWB-P