Code: E407
Description: Abnormally high toner density detected Black TCR Sensor
- Mixture ratio of the toner and carrier in the developing machine is higher than the specified value.
- Mixture ratio of the toner and carrier in the developing machine is higher than the specified value.
Causes: • Photoconductor Unit /K • Mechanical Control Board (PWB-M) • Controller Board (PWB-P)
Remedy: 1 Clean the TCR Sensor window on the underside of the Photoconductor Unit if dirty. - - 2 Reinstall Photoconductor Unit - - 3 Change Photoconductor Unit /K - - 4 Change PWB-M - - 5 Change PWB-P